WS9290B-24-220-X300
  • WS9290B-24-220-X300总装图.pdf WS9290B-24-220-X300总装图.pdf
Share This Product:
  • DESCRIPTION

high pressure ICU ventilator dc blower/dc electric blower exhaust centrifugal turbo warm air blower fan IP54 small size for industrial packing machine

Blower features

 

Brand name: Wonsmart

High pressure with dc brushless motor

Blower type: Centrifugal fan

Voltage:24vdc

Bearing: NMB ball bearing

Type: Centrifugal Fan

Applicable Industries:Manufacturing Plant

Electric Current Type: DC

Blade Material: plastic

Mounting: Ceiling Fan

Place of Origin:Zhejiang, China

Certification: ce, RoHS, ETL

Warranty: 1 Year

After-sales Service Provided: Online support

Life time(MTTF): >20,000hours (under 25 degree C)

Weight: 490 grams

Housing material:PC

Unit size: D90*L114

Motor type:Three Phase DC Brushless Motor

Controller: external

Static pressure: 13 kPa


Blower Performance

 

WS9290B-24-220-X300 blower can reach maximum 38m3/h airflow at 0 kpa pressure and maximum 13kpa static pressure.It has maximum output air power when this blower run at 7kPa resistance if we set 100% PWM, It has maximum efficiency when this blower run at 7kPa resistance if we set 100% PWM.Other load point performance refer to below P-Q curve:



DC brushless blower advantage:

 

(1)WS9290B-24-220-X300blower is with brushless motors and NMB ball bearings inside which indicates very long life time; MTTF of this blower can reach more than 20,000hours at 20degree C environmental temperature

(2)This blower needs no maintence

(3)This blower drived by a brushless motor controller have many different control functions such as speed regulation,speed pulse output,fast acceleration, brake etc.it can be controlled by intelligent machine and equipment easily

(4) Drived by brushless motor driver the blower will have over current, under/over voltage,stall protections.

 

 

Applications:

This blower can be widely used onto air pollution detector,air bed,air cushion machine and ventilators.

 

How to use the blower correctly:

 

This blower can run at CCW direction only.Reverse the impeller running direction can not change the air direction.

Filter onto the inlet to protect the blower from dust and water.

Keep the environmental temperature as low as possible to make the blower life time longer.

Feedback form contact with us